CompanyCompanyCompanyCompanyCompanyCompany

 
 FIRE SYSTEM
 INTRUSION SYSTEM
 MAGNETIC LOCKS
 CCTV
 ACCESS CONTROL
 MONITORING
 LEASE
 
   

Kingdom Alarms is authorized dealer of Silent Knight�s Farenhyt systems.

FIRE ALARM CONTROL PANELS

IntelliKnight 5820XL

The modular design features an easy-to-use interface that simplifies procedures. Plus, this incredibly smart system can differentiate between smoke and dust particles. With IntelliKnight, you'll be notified if you need the fire department or just a maintenance crew. And you'll know exactly where to find the problem.

The lntelliknight system uses data from the sensors installed on the signalling line circuits (SLC) to set sensitivity levels for each of the zones in the system. In addition, the Model 5820XL uses the data to perform drift compensation and sensitivity checks on each of the sensors in the system.

FEATURES

  • Up to 508 addressable points.
  • Supports Class A configuration for SLC (Style 6), SBUS, and Flexput circuits.
  • Distributed, intelligent power.
  • Drift compensation.
  • Flexput I/O circuits.
  • ANSI cadence pattern.
  • Built-in annunciator with 80-character LCD display.
  • RS-485 bus provides communication to system accessories.
  • Built-in RS-232 interface for programming via PC.
  • Built-in digital communicator.
  • Central station reporting by Point or by Zone.
  • Form C trouble relay rated at 2.5 amps at 24 VDC.
  • Two Form C programmable relays rated at 2.5 amps at 24VDC.
  • Uses standard wire - no shielded or twisted pair required.
 

 

IntelliKnight 5808XL

The IntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, and easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered to this powerful FACP from Silent Knight.

The lntelliknight 5808 performs drift compensation and calibration checks on each of the sensors in the system. The basic IntelliKnight 5808 system can be enhanced by adding modules such as the Model 5860 Remote Annunciator, the Model 5824 Serial/Parallel Interface (for printing system reports), and an Intelligent Power Module. The Model 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location.

FEATURES

  • Up to 127 addressable points.
  • Uses standard wire - no shielded or twisted pair required.
  • Built-in digital communicator.
  • Central Station Reporting by Point or Zone.
  • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC.
  • Distributed, intelligent power.
  • Drift compensation.
  • 13 pre-programmed output cadences, (including ANSI-3.41), and 4 programmable outputs.
  • Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power.
  • Built-in annunciator with 80-character LCD display.
  • RS-485 bus provides communication to system accessories.
  • Built-in RS-232 interface for programming via PC.
  • Built-in Form C trouble relay rated at 2.5 amps at 24 VDC.
  • Two Form C programmable relays rated at 2.5 amps at 24VDC.
 

 

IntelliKnight 5700XL

IntelliKnight Model 5700 is a 50 point class leading single loop addressable fire alarm control/communicator system that provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, that includes an easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight.

FEATURES

  • Up to 50 addressable points.
  • Up to 125 zones and 125 output groups.
  • Uses standard wire - no shielded or twisted pair required.
  • Built-in digital communicator.
  • Central Station Reporting by Point or Zone.
  • Supports Class B (Style 4) and Class A (Style 6) configuration for SLC.
  • Distributed, intelligent power.
  • Drift compensation.
  • 13 pre-programmed output cadences, (including ANSI-3.41), and 4 programmable outputs.
  • Notification circuits can be configured as 1 Class A (Style Z) or 2 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power.
  • Built-in synchronization for appliances from Gentex�, Faraday, System Sensor�, and Wheelock�.
  • Built-in annunciator with 80-character LCD display.
  • RS-485 bus provides communication to system accessories.
  • Up/Downloading programming, event history, or detector status via remote or direct connection.
  • Built-in RS-232 interface for programming via PC.
  • Built-in Form C trouble relay rated at 2.5 amps at 24 VDC.
  • Two Form C programmable relays rated at 2.5 amps at 24VDC.

FIRE ALARM COMPONENTS


Single and Dual Action Conventional Pull Stations

The PS-DA/PS-SA Pull Stations are non-coded manual pull stations which provide a Fire Alarm Control Panel (FACP) with a single alarm initiating input signal. The PS-DA/PS-SA pull stations includes both single-action and dual-action models equipped with key lock / reset. It was designed to meet multiple applications with the installer and end-user in mind. Its innovative design, durable construction, and multiple mounting options make the PS-DA and PS-SA simple to install, maintain, and operate.

The single-action pull-station is activated by a single pull-down of the alarm handle. The dual-action versions require pushing in the handle, then pulling the handle down for activation. The PS-DA/PS-SA manual pull stations are UL listed and meet the ADA requirement of a 5-lbs. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. Molded terminal numbers can be found adjacent to the wiring terminals.

FEATURES

  • UL Listed.
  • CSFM Listed.
  • Meets ADA requirements.
  • Operating instructions are molded into the handle along with Braille text.
  • Made of durable Lexan
  • Available in Spanish.
  • Key resettable.
  • Easy to install and operate.
  • Single or dual action.
  • Surface mount box available
 

 

Wall Speaker/Strobes

Selectable output speaker/strobes offer average current draws lower than similar selectable candela products. In addition, the broad frequency response range and low harmonic distortion provided by SpectrAlert speaker technology provides an accurate and intelligible broadcast of evacuation messages.

Selectable Output Speaker/Strobes incorporate the same stylish, low profile design as the conventional SpectrAlert products, for a consistent and aesthetically pleasing appearance across the entire product line.

FEATURES

  • Fidelity sound quality (SP2)
  • Enhanced SPL (SP3)
  • Operates on either 12V or 24V
  • Widest range of candela options:
  • 12V: 15 and 15/75 candela options
  • 24V: 15, 15/75, 30, 75, and 110 candela options
  • Easy candela selection
  • 25.0 and 70.7 volt speaker with four field-selectable power taps
  • Field-reversible strobe for left- or right-mounting
  • Synchronizable with MDL Sync�Circuit� Module
  • Optional surface-mount back box skirt available
 

 

Plug-in Smoke Detectors

System Sensor 100 Series Plug-in Smoke Detectors Series is designed to meet the performance criteria designated by UL. Its sensing chambers are sealed against back pressure air flow, dirt, and insects. This chamber is protected by a fine mesh screen which can be cleaned or replaced. Additional key features include a variety of mounting bases and a full line of accessories.

All 100 Series photoelectric smoke detectors contain a unique optical sensing chamber designed to sense smoke particles produced by a wide range of combustion sources. A custom integrated circuit incorporates signal processing to reduce false alarms.

FEATURES

  • Low current draw.
  • Stable performance in high air velocities.
  • Built-in tamper resistant base design.
  • Remote LED option.
  • Removable cover.
  • Built-in test switch.
       

�2007 KingdomAlarms,LLCC
   